Nexperia
74HC1G66-Q100; 74HCT1G66-Q100
Single-pole single-throw analog switch
Table 9. Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); CL = 50 pF; RL = 1 k, unless otherwise specified;
For test circuit, see Figure 10.
Symbol Parameter
Conditions
40 C to +85 C
40 C to +125 C Unit
Min Typ[1] Max Min
Max
tdis
disable time
E to Y or Z; see Figure 9
[2]
VCC = 2.0 V
-
27
190
-
225 ns
VCC = 4.5 V
-
16
38
-
45 ns
VCC = 5.0 V; CL = 15 pF
-
11
-
-
-
ns
VCC = 6.0 V
-
14
33
-
38 ns
VCC = 9.0 V
CPD
power dissipation VI = GND to VCC
capacitance
-
12
16
-
[3]
-
9
-
-
20 ns
-
pF
74HCT1G66-Q100
tpd
propagation delay Y to Z or Z to Y; RL = ;
[2]
see Figure 8
ten
enable time
VCC = 4.5 V
E to Y or Z; see Figure 9
-
[2]
3
15
-
18 ns
VCC = 4.5 V
-
15
30
-
36 ns
tdis
disable time
VCC = 5.0 V; CL = 15 pF
E to Y or Z; see Figure 9
-
12
-
-
[2]
-
ns
VCC = 4.5 V
-
13
44
-
53 ns
VCC = 5.0 V; CL = 15 pF
CPD
power dissipation VI = GND to VCC 1.5 V
capacitance
-
12
-
-
[3]
-
9
-
-
-
ns
-
pF
[1] All typical values are measured at Tamb = 25 C.
[2] tpd is the same as tPLH and tPHL.
ten is the same as tPZL and tPZH.
tdis is the same as tPLZ and tPHZ.
[3] CPD is used to determine the dynamic power dissipation PD (W).
PD = CPD VCC2 fi + ((CL CSW) VCC2 fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
CSW = maximum switch capacitance in pF (see Table 7);
VCC = supply voltage in Volt;
((CL CSW) VCC2 fo) = sum of outputs.
74HC_HCT1G66_Q100
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 16 September 2013
© Nexperia B.V. 2017. All rights reserved
8 of 19