datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

PX500-U4I 데이터 시트보기 (PDF) - C AND D TECHNOLOGIES

부품명
상세내역
제조사
PX500-U4I
CANDD
C AND D TECHNOLOGIES 
PX500-U4I Datasheet PDF : 4 Pages
1 2 3 4
Input Specifications
Parameter
Operating Range
Inrush Current Limiting
Efficiency
Power Factor Correction (PFC)
Conditions
47-63 Hz
120VAC, cold start
240VAC, cold start
120VAC, full load
240VAC, full load
Min
90
Meets IEC 1000-4-7/EN61000-2-3 (formerly IEC 555-2)
Typ
70%
75%
Max
264
Units
VAC
30
APK
70
APK
0.99
Remote Sense
Remote Sense is provided on Output #1 and will com-
pensate for 1.0V of line drop. Remote Sense leads are
protected against open, short and reversal.
Remote On/Off (Optional)
The power supply is turned on with a TTL logic ‘1’ (or
open) signal and turned off by a switch closure or TTL
logic ‘0’ referenced to (-) sense terminal. Consult the
factory for other options.
Over Voltage Protection
Output #1: 6.5V, ±0.5 VDC
The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Transient Response
The peak output voltage excursion will not exceed 2% and
will recover within 1% in 400 µsec for a 25% step load.
Output Isolation
All outputs are fully isolated.
N+1 Load Share
Output #1 has active load sharing circuitry. Units will load
share within 1.0% of Maximum Rated Load.
Power Fail Signal
Upon AC input voltage removal, the power fail signal
drops to logic zero at least 5msec before loss of DC
output. Upon AC input turn-on, signal remains low until
outputs are in regulation. Consult the factory for other
options.
Over Temperature Protection
Internal thermal switch turns off power supply if over-
heating occurs and automatically restarts. Automatic
restart when temperature drops below threshold.
Safety
UL Recognized: UL File Number E14675 (1950 & 1012)
CSA Certified: CSA File Number LR 9070-154C
(C22.2 No9. 234-M90, Level 6)
TUV License Number: R9576030 (EN60950) (IEC950)
Cooling
The unit is designed to operate with 40 CFM of airflow.
Page 2
PX500 1/98 REV A

Share Link: 