datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

EMC1403 데이터 시트보기 (PDF) - Microchip Technology

부품명
상세내역
제조사
EMC1403 Datasheet PDF : 55 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
1°C Temperature Sensor with Beta Compensation
Data Sheet
4.2
Write Byte
The Write Byte is used to write one byte of data to the registers as shown below Table 4.2:
SLAVE
START ADDRESS
WR
1 -> 0
1001_100
0
Table 4.2 Write Byte Protocol
ACK
0
REGISTER
ADDRESS
XXh
ACK
0
REGISTER
DATA
XXh
ACK
0
STOP
0 -> 1
4.3
Read Byte
The Read Byte protocol is used to read one byte of data from the registers as shown in Table 4.3.
Table 4.3 Read Byte Protocol
START
SLAVE
ADDRESS
WR ACK
1 -> 0 1001_100 0 1
REGISTER
ADDRESS
XXh
ACK START
SLAVE
ADDRESS
RD ACK
0 1 -> 0 1001_100 1 1
REGISTER
DATA
XX
NACK STOP
1 0 -> 1
4.4
Send Byte
The Send Byte protocol is used to set the internal address register pointer to the correct address
location. No data is transferred during the Send Byte protocol as shown in Table 4.4.
START
1 -> 0
SLAVE
ADDRESS
1001_100
Table 4.4 Send Byte Protocol
REGISTER
WR
ACK
ADDRESS
0
0
XXh
ACK
0
STOP
0 -> 1
4.5
Receive Byte
The Receive Byte protocol is used to read data from a register when the internal register address
pointer is known to be at the right location (e.g. set via Send Byte). This is used for consecutive reads
of the same register as shown in Table 4.5.
START
1 -> 0
SLAVE
ADDRESS
1001_100
Table 4.5 Receive Byte Protocol
RD
ACK
REGISTER DATA NACK
1
0
XXh
1
STOP
0 -> 1