RATING AND CHARACTERISTIC CURVES ( AR2500 - AR2512 )
FIG.1 - DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
25
20
15
10
5
0
120 130 140 150 160 170 180 190
CASE TEMPERATURE, ( °C)
FIG.2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
500
Ta = 25 °C
400
300
200
100
0
1
2
4 6 10 20
40 60 100
NUMBER OF CYCLES AT 60Hz
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
100
10
Pulse Width = 300 μs
2% Duty Cycle
1.0
TJ = 25 °C
0.1
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
FORWARD VOLTAGE, VOLTS
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
10
Ta = 100 °C
1.0
0.1
Ta = 25 °C
0.01
0
20
40
60
80 100 120 140
PERCENT OF RATED REVERSE
VOLTAGE, (%)
Page 2 of 2
Rev. 03 : March 14, 2006