ADuM1100
Data Sheet
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance2
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Symbol Min Typ Max Unit Test Conditions
RI-O
1012
Ω
CI-O
1.0
pF f = 1 MHz
CI
4.0
pF
θJCI
46
°C/W Thermocouple located at
θJCO
41
°C/W center of package underside
Package Power Dissipation
PPD
240 mW
1 The device is considered a 2-terminal device; Pin 1, Pin 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
2 Input capacitance is measured at Pin 2 (VI).
REGULATORY INFORMATION
The ADuM1100 is approved by the following organizations.
Table 5.
UL
Recognized under 1577
component recognition program1
Single/basic insulation,
2500 V rms isolation voltage
File E214100
CSA
Approved under CSA Component
Acceptance Notice #5A
Basic insulation per CSA 60950-1-03 and IEC 60950-1,
400 V rms (565 V peak) maximum working voltage
File 205078
VDE
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10):2006-122
Reinforced insulation, 560 V peak
File 2471900-4880-0001
1 In accordance with UL 1577, each ADuM1100 is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 μA).
2 In accordance with DIN V VDE V 0884-10, each ADuM1100 is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Minimum External Air Gap (Clearance)
Symbol Value
Unit
L(I01)
4.90 min mm
Minimum External Tracking (Creepage)
L(I02)
4.01 min mm
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Isolation Group
Maximum Working Voltage Compatible with
50 Years Service Life
VIORM
0.016 min
>175
IIIa
565
mm
V
V peak
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table I)
Continuous peak voltage across the isolation barrier
Rev. I | Page 10 of 20