MC10EP33, MC100EP33
Table 6. 10EP DC CHARACTERISTICS, PECL (VCC = 5.0 V, VEE = 0 V (Note 1))
−40°C
25°C
85°C
Symbol
Characteristic
IEE Power Supply Current
VOH Output HIGH Voltage (Note 2)
VOL Output LOW Voltage (Note 2)
VIH Input HIGH Voltage (Single-Ended)
VIL Input LOW Voltage (Single-Ended)
VBB Output Voltage Reference
VIHCMR Input HIGH Voltage Common Mode
Range (Differential Configuration) (Note 3)
Min
18
3865
3065
3790
3065
3490
2.0
Typ
26
3990
3190
3590
Max
40
4115
3315
4115
3390
3690
5.0
Min
18
3930
3130
3855
3130
3555
2.0
Typ
26
4055
3255
3655
Max
40
4180
3380
4180
3455
3755
5.0
Min
18
3990
3190
3915
3190
3615
2.0
Typ
26
4115
3315
3715
Max Unit
40 mA
4240 mV
3440 mV
4240 mV
3515 mV
3815 mV
5.0 V
IIH
Input HIGH Current
150
150
150 mA
IIL
Input LOW Current
0.5
0.5
0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input and output parameters vary 1:1 with VCC. VEE can vary +2.0 V to −0.5 V.
2. All loading with 50 W to VCC − 2.0 V.
3. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential
input signal.
Table 7. 10EP DC CHARACTERISTICS, NECL (VCC = 0 V; VEE = −5.5 V to −3.0 V (Note 1))
−40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
IEE
VOH
Power Supply Current
Output HIGH Voltage (Note 2)
18
26
40
18
26
40
18
26
40 mA
−1135 −1010 −885 −1070 −945 −820 −1010 −885 −760 mV
VOL
VIH
VIL
VBB
VIHCMR
Output LOW Voltage (Note 2)
Input HIGH Voltage (Single-Ended)
Input LOW Voltage (Single-Ended)
Output Voltage Reference
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(Note 3)
−1935 −1810 −1685 −1870 −1745 −1620 −1810 −1685 −1560 mV
−1210
−885 −1145
−820 −1085
−760 mV
−1935
−1610 −1870
−1545 −1810
−1485 mV
−1510 −1410 −1310 −1445 −1345 −1245 −1385 −1285 −1185 mV
VEE+2.0
0.0
VEE+2.0
0.0
VEE+2.0
0.0 V
IIH
Input HIGH Current
150
150
150 mA
IIL
Input LOW Current
0.5
0.5
0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input and output parameters vary 1:1 with VCC.
2. All loading with 50 W to VCC − 2.0 V.
3. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential
input signal.
www.onsemi.com
4