D.C. OPERATING CHARACTERISTICS (Continued)
(Over the recommended operating conditions unless otherwise specified)
Symbol
Parameter
Second Supply Monitor
IV2
V2MON Current
VTRIP2(5) V2MON Trip Point Voltage Range
Min. Typ.(4) Max.
15
1.7
4.75
0.9
3.5
2.85
2.9
2.95
2.55
2.6
2.65
1.65
1.7
1.75
1.25
1.3
1.35
0.95
1.0
1.05
Unit
Test Conditions
µA
V X40010/11
V X40014/15
V X40010/11-A
V X40010/11-B
V X40010/11-C
V X40014/15-A&B
V X40014/15-C
Notes: (1) The device enters the Active state after any start, and remains active until: 9 clock cycles later if the Device Select Bits in the Slave
Address Byte are incorrect; 200ns after a stop ending a read operation; or tWC after a stop ending a write operation.
(2) The device goes into Standby: 200ns after any stop, except those that initiate a high voltage write cycle; tWC after a stop that initiates a
high voltage cycle; or 9 clock cycles after any start that is not followed by the correct Device Select Bits in the Slave Address Byte.
(3) VIL Min. and VIH Max. are for reference only and are not tested.
(4) At 25°C, VCC = 5V.
(5) See Ordering Information for standard programming levels. For custom programmed levels, contact factory.
(6) Based on characterization data.
EQUIVALENT INPUT CIRCUIT FOR VxMON (x = 1, 2)
R
V
Vref
VxMON
+
C
VREF
Output Pin
tRPDX = 5µs worst case
V = 100mV
CAPACITANCE
Symbol
COUT(1)
CIN(1)
Parameter
Output Capacitance (SDA, RESET, RESET, V2FAIL,
WDO)
Input Capacitance (SCL)
Note: (1) This parameter is not 100% tested.
Max.
8
6
Unit
pF
pF
Test Conditions
VOUT = 0V
VIN = 0V
15
FN8111.0
March 28, 2005