Micrel, Inc.
SY10EL52
SY100EL52
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = GND
Symbol
Parameter
TA = –40°C
TA = 0°C
TA = +25°C
TA = +85°C
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
IEE
Power Supply 10EL — 21 25 17 21 25 17 21 25 17 21 25 mA
Current
100EL — 21 25 17 21 25 17 21 25 19 24 29
VEE
Power Supply 10EL –4.75 –5.2 –5.5 –4.75 –5.2 –5.5 –4.75 –5.2 –5.5 –4.75 –5.2 –5.5 V
Voltage
100EL –4.20 –4.5 –5.5 –4.20 –4.5 –5.5 –4.20 –4.5 –5.5 –4.20 –4.5 –5.5
IIH
Input HIGH Current
— — 150 — — 150 — — 150 — — 150 µA
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = GND
Symbol
fMAX
tPD
tS
tH
tPW
VPP
VCMR
tr
tf
Parameter
TA = –40°C
Min. Typ. Max.
Maximum Toggle
Frequency
1.8 2.5 —
Propagation Delay to
Output
CLK 235 335 515
Set-up Time
125 0 —
Hold Time
150 50 —
Minimum Pulse Width 400 — —
Minimum Input Swing(1) 150 — —
Common Mode Range(2)
D (10EL)
–0.4 — –1.6
D (100EL)
–0.4 — –1.2
CLK (10EL)
–0.6 — (3)
CLK (100EL)
–0.8 — (3)
Output Rise/Fall Times Q 100 225 350
(20% to 80%)
TA = 0°C
Min. Typ. Max.
2.2 2.8 —
275 365 465
125 0 —
150 50 —
400 — —
150 — —
–0.4 — –1.6
–0.4 — –1.2
–0.6 — (3)
–0.8 — (3)
100 225 350
TA = +25°C
Min. Typ. Max.
2.2 2.8 —
275 365 465
125 0 —
150 50 —
400 — —
150 — —
–0.4 — –1.6
–0.4 — –1.2
–0.6 — (3)
–0.8 — (3)
100 225 350
TA = +85°C
Min. Typ. Max.
2.2 2.8 —
320 410 510
125 0 —
150 50 —
400 — —
150 — —
–0.4 — –1.6
–0.4 — –1.2
–0.6 — (3)
–0.8 — (3)
100 225 350
Unit
GHz
ps
ps
ps
ps
mV
V
ps
NOTES:
1. Minimum input swing for which AC parameters are guaranteed.
2. The CMR range is referenced to the most positive side of the differential input signal. Normal operation is obtained if the HIGH level falls within the specified
range and the peak-to-peak voltage lies between VPP min. and 1V.
3. The lower end of the CMR range is dependent on VEE and is equal to VEE + 3.0V.
M9999-121205
hbwhelp@micrel.com or (408) 955-1690
3