NCV7381
Internal Flags
The NCV7381 control logic uses a number of internal flags (i.e. one−bit memories) reflecting important conditions or events.
Table 3 summarizes the individual flags and the conditions that lead to a set or reset of the flags.
Table 3. INTERNAL FLAGS
Flag
Set Condition
Local
Wakeup
Low level detected on WAKE pin in a low−
power mode
Remote
Wakeup
Remote wakeup detected on the bus in a
low−power mode
Wakeup
Local Wakeup flag changes to set
or
Remote Wakeup flag changes to set
Power−on
Thermal
Warning
Internal power supply of the chip becomes
sufficient for the operation of the control logic
Junction temperature is higher than Tjw
(typ. 140°C) in a normal−power mode
and
VBAT is not in under−voltage
Thermal
Shutdown
Junction temperature is higher than Tjsd
(typ. 165°C) in a normal−power mode
and
VBAT is not in under−voltage
TxEN
Timeout
Bus Error
TxEN is Low for longer than dBDTxAct-
iveMax (typ. 1.5 ms) and bus driver is in
Normal mode
Transmitter is enabled
and
Data on bus are different from TxD signal
(sampled after each TXD edge)
VBAT Under− VBAT is below the under−voltage threshold
voltage
for longer than dBDUVVBAT
VCC Under− VCC is below the under−voltage threshold for
voltage
longer than dBDUVVCC
VIO Under−
voltage
VIO is below the under−voltage threshold for
longer than dUVIO
Error
Any of the following status bits is set:
• Bus error
• Thermal Warning
• Thermal Shutdown
• TxEN Timeout
• VBAT Under−voltage
• VCC Under−voltage
• VIO Under−voltage
Reset Condition
Low−power mode is entered
Low−power mode is entered
Normal mode is entered
or
Low−power mode is entered
or
Any under−voltage flag becomes set
Normal mode is entered
(Junction temperature is below Tjw in
a normal−power mode
or
the status register is read in a low−power
mode)
and
VBAT is not in under−voltage
Junction temperature is below Tjsd in
a normal−power mode
and
falling edge on TxEN
and
VBAT is not in under−voltage
TxEN is High or Normal mode is left
(Transmitter is enabled
and
Data on bus are identical to TxD signal)
or
Transmitter is disabled
VBAT is above the under−voltage threshold
for longer than dBDRVBAT
or
Wake flag becomes set
VCC is above the under−voltage threshold
for longer than dBDRVCC
or
Wake flag becomes set
VIO is above the under−voltage threshold for
longer than dBDRVIO
or
Wake flag becomes set
All of the following status bits are reset:
• Bus error
• Thermal Warning
• Thermal Shutdown
• TxEN Timeout
• VBAT Under−voltage
• VCC Under−voltage
• VIO Under−voltage
Comment
The thermal warning
flag has no influence
on the bus driver
function
The transmitter is
disabled as long as
the thermal shut-
down flag is set
The transmitter is
disabled as long as
the timeout flag is set
The bus error flag
has no influence on
the bus driver func-
tion
www.onsemi.com