M74HCT4052
DC SPECIFICATIONS
Test Condition
Value
Symbol Parameter
VIHC High Level Input
Voltage
VILC Low Level Input
Voltage
RON ON Resistance
∆RON Difference of ON
Resistance
between switches
IOFF Input/Output
Leakage Current
(SWITCH OFF)
IIZ
II
ICC
∆ICC
Switch Input
Leakage Current
(SWITCH ON,
OUTPUT OPEN)
Input Leakage
Current
Quiescent Supply
Current
Additional
Quiescent Supply
Current per input
pin
VCC VEE
(V) (V)
TA = 25°C
-40 to 85°C
-55 to
125°C
Min. Typ. Max. Min. Max. Min. Max.
4.5
to
2.0
5.5
4.5
to
5.5
4.5 GND VI = VIHC or VILC
4.5
-4.5
VI/O = VCC to VEE
II/O ≤ 2mA
4.5 GND VI = VIHC or VILC
4.5
-4.5
VI/O = VCC or VEE
II/O ≤ 2mA
4.5 GND VI = VIHC or VILC
4.5
-4.5
VI/O = VCC or VEE
II/O ≤ 2mA
5.5 GND VOS = VCC or GND
5.5
-6.0
VIS = GND or VCC
VI = VILC or VIHC
5.5 GND VOS = VCC or GND
VI = VIHC or VILC
5.5 -6.0
2.0
2.0
0.8
85 180
55 120
70 150
50 100
10 30
5 12
±0.06
± 0.1
±0.06
± 0.1
0.8
225
150
190
125
35
15
± 0.6
±1
± 0.6
±1
0.8
270
180
230
150
45
18
± 1.0
±1
± 1.0
±1
5.5 GND VI = VCC or GND
± 0.1
± 0.1
±1
5.5
5.5
GND
-6.0
VI = VCC or GND
4
40
80
8
80
160
4.5
VI = VCC - 2.1V
to GND other input at VCC
100 360
450
490
5.5
or GND
Unit
V
V
Ω
Ω
µA
µA
µA
µA
µA
4/14