datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

LY1-DC 데이터 시트보기 (PDF) - OMRON Corporation

부품명
상세내역
제조사
LY1-DC
Omron
OMRON Corporation 
LY1-DC Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LY
LY
s COIL DATA(continued)
3-pole type – AC
Rated
voltage (V)
6
12
24
50
100/110
120
200/220
240
Rated current (mA)
50 Hz
60 Hz
310
270
159
134
80
67
38
33
15.90/18.30 13.60/15.60
17.30
14.8
10.50/11.60 9.00/9.90
9.40
8
Coil
resistance
()
6.70
24
100
410
2,300
2,450
8,650
10,400
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.03
0.05
0.12
0.21
0.44
0.79
2.24
3.87
10.50
18.50
11.50
20.60
34.80
59.50
38.60
74.60
Pick-up
voltage
Dropout
voltage
(% of rated voltage)
80% max. 30% min.
Maximum
voltage
110%
Power
consumption
(VA, W)
Approx.
1.60 to 2.00
(60 Hz)
3-pole type – DC
Rated
voltage (V)
6
12
24
48
100/110
Rated current (mA)
234
112
58.60
28.20
12.70/13
Coil
resistance
()
25.70
107
410
1,700
8,500
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.11
0.21
0.45
0.98
1.89
3.87
8.53
13.90
29.60
54.30
Pick-up
voltage
Dropout
voltage
(% of rated voltage)
80% max. 10% min.
Maximum
voltage
110%
Power
consumption
(VA, W)
Approx.
1.40
4-pole type – AC
Rated
voltage (V)
6
12
24
50
100/110
120
200/220
240
Rated current (mA)
50 Hz
60 Hz
386
330
199
170
93.60
80
46.80
40
22.50/25.50 19/21.80
19.00
16.40
11.50/13.10 9.80/11.20
11.00
9.50
Coil
resistance
()
5
20
78
350
1,800
2,200
6,700
9,000
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.02
0.04
0.10
0.17
0.38
0.67
1.74
2.88
10.50
17.30
9.30
19
33.10
57.90
33.20
63.40
Pick-up
voltage
Dropout
voltage
(% of rated voltage)
80% max. 30% min.
Maximum
voltage
110%
Power
consumption
(VA, W)
Approx.
1.95 to 2.50
(60 Hz)
4-pole type – DC
Rated
voltage (V)
6
12
24
48
100/110
Rated current (mA)
240
120
69
30
15/15.90
Coil
resistance
()
25
100
350
1,600
6,900
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.09
0.21
0.39
0.84
1.41
2.91
6.39
13.60
32
63.70
Pick-up
voltage
Dropout
voltage
(% of rated voltage)
80% max. 10% min.
Maximum
voltage
110%
Power
consumption
(VA, W)
Approx.
1.50
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for
AC rated current, and ±15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Class B coil insulation is available.
4

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]