LCP-06008A-16
(13)Design guidance for touchpanel(T/P)
(1) If an consumer will put a palm on housing in normal usage, care should be taken as follows.
(2) Keep the gap, for example 0.3 to 0.7mm,between bezel edge and T/P surface.
The reason is to avoid the bezel edge from contacting T/P surface that may cause a “short”
with bottom layer(See Fig.2)
(3) Insertion a cushion material is recommended.
(4) The cushion material should be limited just on the busbar insulation paste area.
If it is over the transparent insulation paste area, a ”short” may be occurred.
(5) There is one where a resistance film is left in the T/P part of the end of the pole.
Design to keep insulation from the perimeter to prevent from mis-operation and so on.
Housing
Cushion material
PET Film
Insulation metal
Transparent
Insulation Paste
Glass
Key Area
Prohibition Area
Fig.2
0.3
~0.7mm
Electrode
Layer