sharp
LQ10D368
SPEC NO. DATE
LD-13305A 2002.9.25
RECORDS OF REVISION
SUMMARY
PAGE
6 ・【Note2】Corrected the condition
At the condition of YL=200cd/m2
→At the condition of IL=6.0mArms
3/4
NOTE
7 7 Timing Characteristics of input signals
Corrected “Timing characteristics”
・Vertical sync. signal
Cycle TV(Mode:400line):Min 445 → 446line
13 9. Optical Characteristics
・Changed the condition of “Viewing Angle Range”
(Widening viewing angle range)
CR≧5 → CR>10
・Changed the measurement condition
①Changed the remark of chromaticity and luminance
Added “IL=6.0mArms, f=35KHz”
②※(typical condition:IL=6.0mArms)→(condition:IL=6.0mArms)
15 11. Handling Precautions
Changed “Handling precautions”
・h)①Laminated film〜 → Protection film〜
②Deleted Ionized air shall〜
・Added “j)”
・Added “m)”
・Added “n)”
12.Packing form
Corrected packing form
・Piling number of cartons:7cartons → 8cartons
・Carton size
: 298(W)×362(D)×295(h)
→497(W)×318(D)×227(h)
・ Total mass of one carton filled with
full modules
:8.0kg → 7.8kg
・Packing form is shown
:Fig.7 → Fig.4