ISL97635
Electrical Specifications
All specifications below are tested at TA = -40°C to +85°C; VIN = 12V, EN = 5V, RSET = 36.6kΩ,
unless otherwise noted. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise
specified. Temperature limits established by characterization and are not production tested. (Continued)
PARAMETER
DESCRIPTION
CONDITION
MIN TYP MAX UNIT
Eff_peak
Peak Efficiency
ΔIOUT/ΔVIN
DMAX
DMIN
fOSC_hi
fOSC_lo
ILX_leakage
Line Regulation
Boost Maximum Duty Cycle
Boost Minimum Duty Cycle
Lx Frequency
Lx Frequency
Lx Leakage Current
VIN = 18V, 54 LEDs, 20mA
each, L = 8.2µH with DCR
106mΩ, TA = +25°C
VIN = 12V, 54 LEDs, 20mA
each, L = 8.2µH with DCR
106mΩ, TA = +25°C
VIN = 6V, 54 LEDs, 20mA
each, L = 8.2µH with DCR
106mΩ, TA = +25°C
Register 0x08, fSW = 1
Register 0x08, fSW = 0
VLX = 36V, EN = 0
91
%
88
%
86
%
0.1
%
82
%
7
%
1.0 1.2 1.3 MHz
550 600 650 kHz
10
µA
REFERENCE
IMATCH
Channel-to-Channel Current Matching
IACC
Current Accuracy
FAULT DETECTION
IOUT = 30mA, BRT = 255
-3.5 ±1 +3.5 %
±3
%
VSC
Short Circuit Threshold Accuracy
Reg0x08 = 0x0F or 0x0B
Reg0x00 = 0xFF
7.8 8
8.8
V
Reg0x08 = 0x0E or 0x0A
Reg0x00 = 0xFF
2.8 3.1 3.8
V
Vtemp_acc
Over-Temperature Threshold Accuracy
VOVPlo
Overvoltage Limit on OVP Pin
OVPhys
OVP Hysteresis
OVPfault
OVP Short Detection Fault Level
SMBus INTERFACE
5
°C
1.17 1.2 1.23 V
20
mV
300
mV
VIL
Guaranteed Range for Data, Clock Input Low Voltage
0.8
V
VIH
Guaranteed Range for Data, Clock Input High Voltage
2.1
VDD V
VOL
SMBus Data Line Logic Low Voltage with 1.1kΩ series
resistor from data bus to SMBDAT pin
IPULLUP = 350µA
0.4
V
SMBus Data Line Logic Low Voltage without series resistor IPULLUP = 4mA
from data bus to SMBDAT pin
0.17 V
ILEAK
Input Leakage On SMBData/SMBClk
VDD
Nominal Bus Voltage
SMBus TIMING SPECIFICATIONS (Note 4)
3V to 5V ±10%
-1
1
µA
2.7
5.5
V
fSMB
tBUF
tHD:STA
SMBus Clock Frequency
Bus Free Time Between Stop and Start Condition
Hold Time After (Repeated) START Condition. After this
Period, the First Clock is Generated
10
100 kHz
4.7
µs
4.0
µs
tSU:STA
tSU:STO
Repeated Start Condition Setup Time
Stop Condition Setup Time
4.7
µs
4.0
µs
5
FN6434.2
December 22, 2008

Share Link: 