COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING
Symbol
Rating
Commercial
Unit CONDITIONS
VTERM
TSTG
IOUT
Terminal Voltage with
Respect to GND
Storage Temperature
DC Output Current
–0.5 to +5
V
–55 to +125
°C
–50 to +50
mA
NOTE:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of the specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
Symbol
Parameter
Min
VCC Supply Voltage(Com’l & Ind’l) 3.0
GND Supply Voltage(Com’l & Ind’l) 0
VIH
Input High Voltage
(Com’l & Ind’l)
2.0
VIL
Input Low Voltage
(Com’l & Ind’l)
TA
Operating Temperature
0
Commercial
Typ.
3.3
0
Max Unit
3.6 V
V
5.0 V
0.8 V
70 °C
TA
Operating Temperature
Industrial
-40
85 °C
DC ELECTRICAL CHARACTERISTICS
(Commercial: VCC = 3.3V ± 0.3V, TA = 0°C to +70°C; Industrial :VCC = 3.3V ± 0.3V, TA = -40°C to +85°C)
Symbol
Parameter
IDT72V801
IDT72V811
IDT72V821
IDT72V831
IDT72V841
IDT72V851
Commercial and Industrial (1)
tCLK = 10, 15, 20 ns
Min.
Typ.
Max.
Unit
ILI(2)
Input Leakage Current (Any Input)
–1
–1
µA
ILO(3)
Output Leakage Current
–10
10
µA
VOH
Output Logic “1” Voltage, IOH = –2 mA
2.4
V
VOL
Output Logic “0” Voltage, IOL = 8 mA
0.4
V
ICC1(4,5,6) Active Power Supply Current (both FIFOs)
40
mA
ICC2(3,7) Standby Current
10
mA
NOTES:
1. Industrial temperature range product for the 15ns speed grade is available as a standard device.
2. Measurements with 0.4 VIN VCC.
3. OEA, OEB VIH, 0.4 VOUT VCC.
4. Tested with outputs disabled (IOUT = 0).
5. RCLK and WCLK toggle at 20 MHz and data inputs switch at 10 MHz.
6. Typical ICC1 = 2[0.17 + 0.48*fS + 0.02*CL*fS] (in mA).
These equations are valid under the following conditions:
VCC = 3.3V, TA = 25°C, fS = WCLK frequency = RCLK frequency (in MHz, using TTL levels), data switching at fS/2, CL = capacitive load (in pF).
7. All Inputs = VCC - 0.2V or GND + 0.2V, except RCLK and WCLK, which toggle at 20 MHz.
CAPACITANCE (TA = +25°C, f = 1.0MHz)
Symbol
CIN(2)
Parameter
Input Capacitance
Conditions
VIN = 0V
Max. Unit
10
pF
COUT(1,2) Output Capacitance
VOUT = 0V
10
pF
NOTE:
1. With output deselected (OEA, OEB VIH).
2. Characterized values, not currently tested.
4