DMV1500SD
Table 3: Absolute Ratings (limiting values, per diode)
Symbol
Parameter
Value
Unit
Damper Modul.
VRRM Repetitive peak reverse voltage
1500
600
V
IFSM Surge non repetitive forward current tp = 10ms sinusoidal
50
50
A
Tstg Storage temperature range
-40 to +150
°C
Tj Maximum operating junction temperature
150
°C
Table 4: Thermal resistances
Symbol
Parameter
Rth(j-c)
Junction to case thermal resistance
Value (max.) Unit
4
°C/W
Table 5: Static Electrical Characteristics
Value
Symbol
Parameter
Test conditions
Tj = 25°C
Typ. Max.
Damper
IR * Reverse leakage current
Modul.
VR = 1500 V
VR = 600 V
100
3
VF ** Forward voltage drop
Damper
Modul.
IF = 6 A
IF = 6 A
1.2 1.75
1.15 1.4
Tj = 125°C
Typ. Max.
100 1000
3
30
1.1 1.5
1 1.25
Pulse test:
* tp = 5 ms, δ < 2%
** tp = 380 µs, δ < 2%
To evaluate the maximum conduction losses of the DAMPER and MODULATION diodes use the following equations :
DAMPER: P = 1.2 x IF(AV) + 0.050 x IF2(RMS)
MODULATION: P = 0.89 x IF(AV) + 0.055 x IF2(RMS)
Unit
µA
V
Table 6: Recovery Characteristics
Value
Symbol
Parameter
Test conditions
Damper
Modul.
Unit
Typ. Max. Typ. Max.
IF = 100mA
IR =100mA
Tj = 25°C 1000 2000 250 400
trr
IRR = 10mA
Reverse recovery time
IF = 1A
ns
dIF/dt = -50 A/µs Tj = 25°C 150 250 60
85
VR =30V
2/8