Input circuit (ESD protection)
V bb
V
ZD
Z,IN
V bIN
IN
I
IN
R bb
V IN
ESD-Zener diode: 67 V typ., max 15 mA;
Data sheet BTS 6144B/P
Inductive and overvoltage output clamp
+ Vbb
VZ1
V ON
OUT
PROFET
VON is clamped to VON(Cl) = 42V typ
Overvoltage protection of logic part
+ Vbb
Current sense output
Normal operation
Vbb Rbb
IIS,fault
ZD
V
Z,IS
R IN
IN
V
Z,IN
V
Z,IS
R bb
Logic
IS
PROFET
VOUT
IS
IIS
VIS
R
IS
VZ,IS = 67 V (typ.), RIS = 1 kΩ nominal (or 1 kΩ /n, if n
devices are connected in parallel). IS = IL/kilis can be
only driven by the internal circuit as long as
Vout - VIS > 5V. Therefore RIS should be less than
Vbb − 5V
7.5mA
.
Note: For large values of RIS the voltage VIS can reach
almost Vbb. See also overvoltage protection.
If you don't use the current sense output in your
application, you can leave it open.
R IS
RV
V Z,VIS
Signal GND
Rbb = 100 Ω typ., VZ,IN = VZ,IS = 67 V typ., RIS = 1 kΩ
nominal. Note that when overvoltage exceeds 67 V typ.
a voltage above 5V can occur between IS and GND, if
RV, VZ,VIS are not used.
Infineon Technologies AG
9 of 16