Data Line Chokes for ISDN
S0 Interface
General technical data
Rated voltage VR
Rated current IR
Rated inductance LR
Inductance tolerance
Inductance decrease ∆L/L0
Stray inductance LS
DC resistance Rtyp
Climatic category
Weight
B82719C2...
42 Vac (50/60 Hz)
80 Vdc
Referred to 50 Hz and 40 °C ambient temperature
Measured with HP 4275A at
L ≤ 1 mH = 100 kHz, 50 mV
L > 1 mH = 10 kHz, 50 mV
(specified per winding)
–30/+50 %
< 10 % at dc magnetic bias with IR
Measured with HP 4275A at 100 kHz and 250 mV
Typical values, measured at 20 °C ambient temperature
40/125/56 (–40 °C/+125 °C/56 days damp heat test)
acc. to IEC 60068-1
Approx. 1,5 g
Characteristics and ordering codes
LR
mH
0,47
1,0
4,7
LS, typ
IR
µH
mA
0,2
450
0,25
400
0,45
250
Rtyp
Ω
0,25
0,3
0,8
VT
V–, 2 s
750
750
750
Ordering code
B82719C2474N315
B82719C2105N365
B82719C2475N365
63 04/02