AN725
5.4.2. Contrast Modes
The LCD0 module features four contrast modes: bypass, minimum, constant, and auto-bypass. The selection of
the contrast mode is governed by the application requirements and LCD specifications. The power consumption of
these modes will vary due to the internal charge pump and resistor string that generates the VLCD voltage.
Reducing the time this hardware is active will reduce power consumption.
In bypass mode shown in Figure 11, the VLCD voltage tracks with the VBAT input voltage. This mode reduces
power consumption by disabling the LCD charge pump and is most appropriate for systems where the VBAT
voltage is relatively constant.
VBAT
VLCD
Figure 11. LCD0 Bypass Contrast Mode
In minimum contrast mode shown in Figure 12, the VLCD voltage will track the VBAT voltage to a minimum level
set by the VBAT monitor threshold (VBMTH). When VBAT is equal to this voltage, VLCD will switch to the contrast
level set by the CTRST field. The threshold and contrast voltages do not have to be set to the same level, as
shown in Figure 13. If the VBAT voltage goes back above the threshold, the LCD contrast charge pump will turn off.
This mode is most efficient for systems that can use the battery voltage most of the time but require a minimum
contrast level to see the LCD segments.
VBAT
VLCD
minimum level set by
CTRST
Figure 12. LCD0 Minimum Contrast Mode
VBAT
VLCD
CTRST
VBMTH
Figure 13. LCD0 Minimum Contrast Mode with Different Threshold and Voltage Settings
Rev. 0.1
23