ADP151
SPECIFICATIONS
VIN = (VOUT + 0.4 V) or 2.2 V, whichever is greater; EN = VIN, IOUT = 10 mA, CIN = COUT = 1 µF, TA = 25°C, unless otherwise noted.
Table 1.
Parameter
Symbol Conditions
Min Typ Max Unit
INPUT VOLTAGE RANGE
OPERATING SUPPLY CURRENT
SHUTDOWN CURRENT
OUTPUT VOLTAGE ACCURACY
VIN
IGND
IGND-SD
TJ = −40°C to +125°C
IOUT = 0 µA
IOUT = 0 µA, TJ = −40°C to +125°C
IOUT = 100 µA
IOUT = 100 µA, TJ = −40°C to +125°C
IOUT = 10 mA
IOUT = 10 mA, TJ = −40°C to +125°C
IOUT = 200 mA
IOUT = 200 mA, TJ = −40°C to +125°C
EN = GND
EN = GND, TJ = −40°C to +125°C
2.2
5.5 V
10
µA
20
µA
20
µA
40
µA
60
µA
90
µA
265
μA
350 μA
0.2
µA
1.0 µA
TSOT/LFCSP
WLCSP
REGULATION
VOUT
IOUT = 10 mA
−1
VOUT
TJ = −40°C to +125°C
VOUT < 1.8 V
100 µA < IOUT < 200 mA, VIN = (VOUT + 0.4 V) to 5.5 V −3
VOUT ≥1.8 V
100 µA < IOUT < 200 mA, VIN = (VOUT + 0.4 V) to 5.5 V −2.5
VOUT
TJ = −40°C to +125°C
VOUT < 1.8 V
100 µA < IOUT < 200 mA, VIN = (VOUT + 0.4 V) to 5.5 V −2.5
VOUT ≥1.8 V
100 µA < IOUT < 200 mA, VIN = (VOUT + 0.4 V) to 5.5 V −2
+1
%
+2
%
+1.5 %
+2
%
+1.5 %
Line Regulation
Load Regulation (TSOT/LFCSP)1
Load Regulation (WLCSP)1
DROPOUT VOLTAGE2
TSOT/LFCSP
WLCSP
∆VOUT/∆VIN
∆VOUT/∆IOUT
∆VOUT/∆IOUT
VDROPOUT
VIN = (VOUT + 0.4 V) to 5.5 V, TJ = −40°C to +125°C
VOUT < 1.8 V
IOUT = 100 µA to 200 mA
IOUT = 100 µA to 200 mA, TJ = −40°C to +125°C
VOUT ≥ 1.8 V
IOUT = 100 µA to 200 mA
IOUT = 100 µA to 200 mA, TJ = −40°C to +125°C
VOUT < 1.8 V
IOUT = 100 µA to 200 mA
IOUT = 100 µA to 200 mA, TJ = −40°C to +125°C
VOUT ≥1.8 V
IOUT = 100 µA to 200 mA
IOUT = 100 µA to 200 mA, TJ = −40°C to +125°C
IOUT = 10 mA
IOUT = 10 mA, TJ = −40°C to +125°C
IOUT = 200 mA
IOUT = 200 mA, TJ = −40°C to +125°C
IOUT = 200 mA
IOUT = 200 mA, TJ = −40°C to +125°C
−0.05
0.006
+0.05
0.012
%/V
%/mA
%/mA
%/mA
0.003
0.008
0.004
0.009
%/mA
%/mA
%/mA
%/mA
%/mA
0.002
10
150
135
0.006
30
230
200
%/mA
%/mA
mV
mV
mV
mV
mV
mV
Rev. D | Page 3 of 24