AD7091
Figure 23 and Figure 24 show the typical power dissipation
vs. throughput rate for the AD7091 at 3 V for the VDD supply.
Figure 24 shows the reduction in power consumption that can
be achieved when power-down mode is used compared with
using only normal mode at lower throughput rates.
1100
VDD = 3V
1000
900
800
700
600
500
400
300
200
100
0
0
200
400
600
800
1000
THROUGHPUT RATE (kSPS)
Figure 23. Power Dissipation vs. Throughput Rate (Full Range)
100
VDD (NO PD)
VDD
10
Data Sheet
MULTIPLEXER APPLICATIONS
A multiplexer can be used in the signal chain to switch multiple
analog input signals to the AD7091. In such applications,
control the multiplexer switch time to ensure accurate analog-
to digital-conversion of the input signals. To allow the AD7091
to fully acquire the input signal, the multiplexer should
switch in the channel to be converted a minimum of 350 ns
before initiating a conversion. The multiplexer should also
hold this channel at the AD7091 for a minimum of 200 ns after
the CONVST falling edge.
1
0.01
0.1
1
10
THROUGHPUT RATE (kSPS)
VDD = 3V
VIN = 0V
100
Figure 24. Power Dissipation vs. Throughput Rate (Lower Range)
Rev. B | Page 14 of 20