Data Sheet
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 3.
Parameter
VDD to GND
Analog Input Voltage to GND
Digital Input Voltage to GND
Digital Output Voltage to GND
Input Current to Any Pin Except
Supplies1
Operating Temperature Range
Storage Temperature Range
Junction Temperature
ESD
Human Body Model (HBM)
Field-Induced Charged Device
Model (FICDM)
Rating
−0.3 V to +7 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
±10 mA
−40°C to +125°C
−65°C to +150°C
150°C
±2.5 kV
±1.5 kV
1 Transient currents of up to 100 mA do not cause silicon controlled rectifier
(SCR) latch-up.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
AD7091
THERMAL RESISTANCE
Table 4. Thermal Resistance
Package Type
θJA
θJC
8-Lead LFCSP
36.67 6.67
ESD CAUTION
Unit
°C/W
Rev. A | Page 5 of 20