STP20NF06 - STF20NF06
1
Electrical ratings
Electrical ratings
Table 1. Absolute maximum ratings
Symbol
Parameter
Value
Unit
TO-220 TO-220FP
VDS
Drain-source voltage (VGS = 0)
60
VGS
ID
ID
IDM(2)
Gate- source voltage
Drain current (continuous) at TC = 25°C
Drain current (continuous) at TC = 100°C
Drain current (pulsed)
± 20
20
20(1)
14
14(1)
80
80(1)
Ptot
Total dissipation at TC = 25°C
60
28
Derating factor
0.4
0.18
dv/dt (3) Peak diode recovery voltage slope
9
EAS (4) Single pulse avalanche energy
120
VISO
Insulation withstand voltage (RMS) from all three
leads to external heat sink (t=1s;TC=25°C)
--
2500
Tstg
Storage temperature
Tj
Max. operating junction temperature
-55 to 175
1. Refer to SOA for the max allowable current value on FP-type due to Rth value
2. Pulse width limited by safe operating area.
3. ISD ≤20A, di/dt ≤200A/µs, VDD ≤V(BR)DSS, Tj ≤TJMAX
4. Starting Tj = 25 °C, ID = 10A, VDD = 30V
V
V
A
A
A
W
W/°C
V/ns
mJ
V
°C
Table 2. Thermal data
Symbol
Parameter
Rthj-case Thermal resistance junction-case max
Rthj-amb Thermal resistance junction-ambient max
TJ
Maximum lead temperature for soldering purpose
TO-220 TO-220FP Unit
2.5
5.35
62.5
300
°C/W
°C/W
°C
3/14