2.4.Lighting Specifications
2.4.1.Absolute Maximum Ratings
Parameter
Symbol
Conditions
Foward Current
IF
Note 1
Reverse Voltage
VR
-
LED Power Dissipation
PD
-
Note 1 : Refer to the foward current derating curve.
IF (mA)
180
Ta=25℃
Min. Typ. Max. Units
-
-
180
mA
-
-
8
V
-
-
0.8
W
105
0
25
50 Ta (℃)
2.4.2.Operating Characteristics
Parameter
Foward Voltage
Luminance of
Backlight Surface
Symbol
VF
L
Conditions
IF=90mA
IF=90mA
Ta=25℃
Min. Typ. Max. Units
3.8
4.0
4.2
V
55
-
-
cd/㎡
DMC16202NYU-LY (AW) No.99-0335
OPTREX CORPORATION
OPTREX
Page 5/16