datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MAX6638 데이터 시트보기 (PDF) - Maxim Integrated

부품명
상세내역
제조사
MAX6638 Datasheet PDF : 19 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Temperature Monitor with
Dual Serial Interface
ABSOLUTE MAXIMUM RATINGS
(All voltages referenced to GND, unless otherwise noted.)
VCC ....................................................................................-0.3V to +6.0V
DXP.............................................................-0.3V to (VCC + 0.3V)
DXN .......................................................................-0.3V to +0.8V
SCK1, SDA1, SCK2, SDA2, ALERT1,
OVERT1, ALERT2 .....................................................-0.3V to +6V
SDA1, SDA2, ALERT1, OVERT1, ALERT2 ..........-1mA to +50mA
DXN Current .......................................................................±1mA
Continuous Power Dissipation (TA = +70°C)
16-Pin TQFN (derate 16.9 mW/°C above +70°C) ....1349 mW
ESD Protection (all pins, Human Body Model) ................±2000V
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = 3.0V to 5.5V, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VCC = 3.3V and TA = +85°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Supply Voltage
Operating Current
VCC
During conversion
ADC not converting
3.0
5.5
V
600
950
µA
80
Standby Supply Current
SMBus1 and SMBus2 static
3
10
µA
TEMPERATURE MEASUREMENT
Remote Diode-Source Current
High level
IRJ
Low level
80
100
120
µA
8
10
12
VCC = 3.3V, TA = +85°C to +100°C,
TRJ = +85°C to +145°C
-1.0
+1.0
Remote Temperature Error
VCC = 3.3V, TA = +25°C to +100°C,
TRJ = +25°C to +145°C
-2.0
+2.0
°C
VCC = 3.3V, TA = +0°C to +125°C,
TRJ = 0°C to +145°C
-3.0
+3.0
Local Temperature Error
Supply Sensitivity of Temperature
Error
VCC = 3.3V, TA = +25°C to +85°C
VCC = 3.3V, TA = 0°C to +125°C
-2.0
+2.0
°C
-3.5
+3.5
±0.2
°C/V
POWER-ON RESET
Power-On-Reset Threshold
POR Threshold Hysteresis
VCC falling
1.9
V
90
mV
Undervoltage-Lockout Threshold
Undervoltage-Lockout Hysteresis
VCC falling
2.30 2.60 2.95
V
90
mV
ANALOG-TO-DIGITAL CONVERTER
Conversion Time
ALERT1, OVERT1, ALERT2, SDA1, SDA2
Nonoverlapping single conversion from
stop bit to conversion complete
23
32
39
ms
Output Low Voltage
Leakage Current
VOL
ILEAK
IOL = 6mA
VOH = 5.5V
0.6
V
±1
µA
2 _______________________________________________________________________________________

Share Link: 