datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

5962R9675501VJC 데이터 시트보기 (PDF) - Intersil

부품명
상세내역
제조사
5962R9675501VJC Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
HS-565ARH
specification given is the larger of the two, representing
worst case drift.
Power Supply Sensitivity
Power Supply Sensitivity is a measure of the change in gain
and offset of the D/A converter resulting from a change in -
15V or +15V supplies. It is specified under DC conditions
and expressed as parts per million of full scale range per
percent of change in power supply (ppm of FSR/%).
Compliance
Compliance Voltage is the maximum output voltage range
that can be tolerated and still maintain its specified accuracy.
Compliance Limit implies functional operation only and
makes no claims to accuracy.
Glitch
A glitch on the output of a D/A converter is a transient spike
resulting from unequal internal ON-OFF switching times.
Worst case glitches usually occur at half scale or the major
carry code transition from 011 . . . 1 to 100 . . . 0 or vice
versa. For example, if turn ON is greater than turn OFF for
011 . . . 1 to 100 . . . 0, an intermediate state of 000 . . . 0
exists, such that, the output momentarily glitches toward
zero output. Matched switching times and fast switching will
reduce glitches considerably.
Applying the HS-565ARH
OP AMP Selection
The HS-565ARH’s current output may be converted to
voltage using the standard connections shown in Figures 1
and 2. The choice of operational amplifier should be
reviewed for each application, since a significant trade-off
may be made between speed and accuracy. Remember
settling time for the DAC-amplifier combination is
(tD)2 + (tA)2
where tD, tA are settling times for the DAC and amplifier.
R2
100
REF OUT
VCC
43
BIP.
OFF.
8
+
-
6
REF
IN
5
REF
GND
19.95
K
HS-565ARH
10V
5K
IREF
0.5mA
9.95K
DAC
5K
3.5K +
-
3K
IO
(4 x IREF
x CODE) 2.5K
100k
100
+15V
R1
50k
-15V
11
20V SPAN
10
10V SPAN VO
DAC
OUT
9
-
C
+
R (SEE
TABLE 7)
CODE
INPUT
7
-VEE
24 . . . . . 13
MSB LSB
PWR
GND
FIGURE 1. UNIPOLAR VOLTAGE OUTPUT
No Trim Operation
The HS-565ARH will perform as specified without calibration
adjustments. To operate without calibration, substitute 50
resistors for the 100trimming potentiometers: In Figure 1
replace R2 with 50; also remove the network on pin 8 and
connect 50to ground. For bipolar operation in Figure 2,
replace R3 and R4 with 50resistors.
With these changes, performance is guaranteed as shown
under Specifications, “External Adjustments”. Typical
unipolar zero will be ±0.50 LSB plus the op amp offset.
The feedback capacitor C must be selected to minimize
settling time.
R4
100
REF OUT
VCC
43
R3
100
BIP.
OFF.
8
+
-
6 19.95K
REF
IN
5
REF
GND
HS-565ARH
10V
5K
IREF
0.5mA
9.95K
DAC
5K
+
3.5K
-
3K
IO
(4 x IREF
x CODE) 2.5K
CODE
INPUT
11
20V SPAN
10
10V SPAN VO
DAC
OUT
9
-
C
+
R (SEE
TABLE 7)
7
-VEE
24 . . . . . 13
MSB LSB
PWR
GND
FIGURE 2. BIPOLAR VOLTAGE OUTPUT
4

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]