datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

IN74HC192D 데이터 시트보기 (PDF) - Integral Corp.

부품명
상세내역
제조사
IN74HC192D Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
IN74HC192
DC ELECTRICAL CHARACTERISTICS(Voltages Referenced to GND)
Symbol
Parameter
Test Conditions
VIH Minimum High-Level VOUT=0.1 V or VCC-0.1 V
Input Voltage
IOUT≤ 20 µA
VIL Maximum Low -
VOUT=0.1 V or VCC-0.1 V
Level Input Voltage IOUT ≤ 20 µA
VOH Minimum High-Level VIN=VIH or VIL
Output Voltage
IOUT ≤ 20 µA
VIN=VIH or VIL
IOUT ≤ 4.0 mA
IOUT ≤ 5.2 mA
VOL Maximum Low-Level VIN=VIH or VIL
Output Voltage
IOUT ≤ 20 µA
IIN
Maximum Input
Leakage Current
VIN=VIH or VIL
IOUT ≤ 4.0 mA
IOUT ≤ 5.2 mA
VIN=VCC or GND
ICC
Maximum Quiescent VIN=VCC or GND
Supply Current
IOUT=0µA
(per Package)
VCC Guaranteed Limit
V 25 °C 85 125 Unit
to
°C °C
-55°C
2.0 1.5 1.5 1.5 V
4.5 3.15 3.15 3.15
6.0 4.2 4.2 4.2
2.0 0.3 0.3 0.3 V
4.5 0.9 0.9 0.9
6.0 1.2 1.2 1.2
2.0 1.9 1.9 1.9 V
4.5 4.4 4.4 4.4
6.0 5.9 5.9 5.9
4.5 3.98 3.84 3.7
6.0 5.48 5.34 5.2
2.0 0.1 0.1 0.1 V
4.5 0.1 0.1 0.1
6.0 0.1 0.1 0.1
4.5 0.26 0.33 0.4
6.0 0.26 0.33 0.4
6.0 ±0.1 ±1.0 ±1.0 µA
6.0 8.0 80 160 µA
FUNCTION TABLE
Inputs
MR PL CPU CPD
HX X
X
LL X
X
LH
H
LH
H
LH H
LH H
X = don’t care
Mode
Reset(Asyn.)
Preset(Asyn.)
No Count
Count Up
Count Down
No Count
The IN74HC192 can be preset to any state, but
will not count beyond 9. If preset to state 10, 11, 12,
13, 14 or 15, it will follow the sequence 10, 11, 6: 12,
13, 4: 14, 15, 2 if counting Up, and follow the
sequence 15, 14, 13, 12, 11, 10, 9 if counting Down.
Logic equations
For Terminal Count:
TCU = Q0 Q3 CPU
TCD = Q0 Q1 Q2 Q3 CPD
253

Share Link: 