Cirrus Logic
DESCRIPTION
VRE117/119 Series Precision Voltage References provide ultrastable +3 V (VRE117), and ±3 V (VRE119) output with ±0.2 mV initial accuracy and temperature coefficient as low as 0.6 ppm/°C over the full military temperature range. This improvement in accuracy is made possible by a unique, proprietary multipoint laser compensation technique. Significant improvements have been made in other performance parameters as well, including initial accuracy, warm-up drift, line regulation, and long-term stability, making the VRE117/119 series the most accurate and stable 3 V reference available.
FEATURES
♦ Very High Accuracy: ±3 V Output, ±0.2 mV
♦ Extremely Low Drift: 0.6 ppm/°C (-55°C to +125°C)
♦ Low Warm-up Drift: 1 ppm Typical
♦ Excellent Stability: 6 ppm/1000 Hrs. Typical
♦ Excellent Line Regulation: 3 ppm/V Typical
♦ Hermetic 14-pin Ceramic DIP
♦ Military Processing Option
APPLICATIONS
♦ Precision A/D and D/A Converters
♦ Transducer Excitation
♦ Accurate Comparator Threshold Reference
♦ High Resolution Servo Systems
♦ Digital Voltmeters
♦ High Precision Test and Measurement Instruments