B32671P ... B32673P
Power Factor Correction
Technical data
Reference standard: IEC 60384-16. All data given at T = 20 °C, otherwise is specified.
Operating temperature
range
Dissipation factor tan δ
(in 10-3) at 20 °C
(upper limit values)
Max. operating temperature Top, max
Upper category temperature Tmax
Lower category temperature Tmin
Rated temperature TR
1 kHz 1.0
10 kHz 2.5
100 kHz 25.0
+125 °C
+110 °C
55 °C
+85 °C
Insulation resistance Rins
at 100 V or time constant
τ = CR Rins at 20 °C,
rel. humidity ≤ 65%
(minimum as-delivered
30 GΩ (CR ≤ 0.33 µF)
10000 s (CR > 0.33 µF)
values)
DC test voltage
Category voltage VC
(continuous operation with
VDC or VAC at f ≤ 1 kHz)
Operating voltage Vop for
short operating periods
(VDC or VAC at f ≤ 1 kHz)
Reliability:
Failure rate λ
Service life tSL
1.4 VR, 2 s
TA (°C)
DC voltage derating AC voltage derating
TA ≤85
VC = VR
VC,RMS = VRMS
85 <TA ≤110 VC = VR (165 Top)/80 VC,RMS = VRMS (165 Top)/80
Top (°C)
DC voltage (max. hours) AC voltage (max. hours)
Top ≤100
Vop = 1.1 VC (1000 h) Vop = 1.0 VC,RMS (1000 h)
100 <Top ≤125 Vop = 1.0 VC (1000 h) Vop = 1.0 VC,RMS (1000 h)
24 fit (≤ 1 10-7/h) at 0.5 VR, 40 °C
200000 h at 0.5 VR, 85 °C
For conversion to other operating conditions and temperatures, refer
to chapter "Reliability", page .
Failure criteria:
Total failure
Short circuit or open circuit
Failure due to variation
of parameters
Capacitance change ∆C/C
Dissipation factor tan δ
Insulation resistance Rins
Or time constant τ
> 10%
> 4 × upper limit values
< 150 MΩ (CR ≤ 0.33 µF)
< 50 s (CR ≥ 0.33 µF)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 18