MBRF1045
ELECTRICAL CHARACTERISTICS
Characteristic
Maximum Instantaneous Forward Voltage (3)
(iF = 20 Amp, TC = 25°C)
(iF = 20 Amp, TC = 125°C)
(iF = 10 Amp, TC = 125°C)
Maximum Instantaneous Reverse Current (3)
(Rated DC Voltage, TC = 25°C)
(Rated DC Voltage, TC = 125°C)
(3) Pulse Test: Pulse Width = 300 µs, Duty Cycle ≤ 2.0%
Symbol
Max
vF
0.84
0.72
0.57
iR
0.1
15
Unit
Volts
mA
100
70
50
30
20
10
7
5
3
2
1
0.7
0.5
0.3
0.2
0.1
0.2
TJ = 150°C
25°C
0.4
0.6
0.8
1
100°C
1.2
1.4
vF, INSTANTANEOUS VOLTAGE (VOLTS)
Figure 1. Maximum Forward Voltage
100
70
50
30
20
10
7
5
3
2
1
0.7
0.5
0.3
0.2
0.1
0.2
TJ = 150°C
25°C
100°C
0.4
0.6
0.8
1
1.2
1.4
vF, INSTANTANEOUS VOLTAGE (VOLTS)
Figure 2. Typical Forward Voltage
100
10
1
0.1
0.01
0.001 0
TJ = 150°C
125°C
100°C
75°C
25°C
10
20
30
40
50
VR, REVERSE VOLTAGE (VOLTS)
Figure 3. Maximum Reverse Current
200
TJ = 125°C, VRRM MAY BE APPLIED
BETWEEN EACH CYCLE OF SURGE
100
70
50
30
20 1
23
5 7 10
20 30 50 70 100
NUMBER OF CYCLES AT 60 Hz
Figure 4. Maximum Surge Capability
2