Fiber Optic Transmitter
MOF-T3C6
Recommended Operating Conditions
Parameter
Operating supply voltage
Operating transfer rate
Symbol
Vcc
T
MIN.
2.75
---
TYP.
---
---
MAX.
5.25
13.2
Unit
V
Mbps
Electro-Optical Characteristics
Parameter
Peak emission wavelength
Optical power output coupling with fiber
Dissipation current
High level input voltage
Low level input voltage
Low →High delay time
High →Low delay time
Pulse width distortion
Symbol
λp
Pc
Icc
ViH
ViL
tpLH
tpHL
∆tw
Conditions
Refer to Fig. 1
Refer to Fig. 2
Refer to Fig. 2
Refer to Fig. 2
Refer to Fig. 3
Refer to Fig. 3
Refer to Fig. 3
MIN.
630
-21
---
2.1
---
---
---
-15
TYP.
660
-18
8
---
---
100
100
---
MAX.
690
-15
13
Vcc
0.8
180
180
+15
Unit
nm
dBm
mA
V
V
ns
ns
ns
Unity Opto Technology Co., Ltd.
2/4
REV : A3