Nexperia
74AHC1GU04-Q100
Inverter
Table 7. Static characteristics …continued
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions
25 C
40 C to +85 C 40 C to +125 C Unit
Min Typ Max Min Max
Min
Max
VOH
HIGH-level VI = VIH or VIL
output voltage IO = 50 A; VCC = 2.0 V 1.9 2.0 -
1.9 -
1.9
-
V
IO = 50 A; VCC = 3.0 V 2.9 3.0 -
2.9 -
2.9
-
V
IO = 50 A; VCC = 4.5 V 4.4 4.5 -
4.4 -
4.4
-
V
IO = 4.0 mA; VCC = 3.0 V 2.58 -
-
2.48 -
2.40 -
V
IO = 8.0 mA; VCC = 4.5 V 3.94 -
-
3.8 -
3.70 -
V
VOL
LOW-level
VI = VIH or VIL
output voltage IO = 50 A; VCC = 2.0 V -
0 0.1 -
0.1
-
0.1
V
IO = 50 A; VCC = 3.0 V -
0 0.1 -
0.1
-
0.1
V
IO = 50 A; VCC = 4.5 V -
0 0.1 -
0.1
-
0.1
V
IO = 4.0 mA; VCC = 3.0 V -
-
0.36 -
0.44
-
0.55
V
IO = 8.0 mA; VCC = 4.5 V -
-
0.36 -
0.44
-
0.55
V
II
input leakage VI = 5.5 V or GND;
current
VCC = 0 V to 5.5 V
--
0.1 -
1.0
-
2.0
A
ICC
supply current VI = VCC or GND; IO = 0 A;
--
1.0 -
10
-
40
A
VCC = 5.5 V
CI
input
capacitance
- 1.5 10 -
10
-
10
pF
11. Dynamic characteristics
Table 8. Dynamic characteristics
GND = 0 V; tr = tf = 3.0 ns. For test circuit see Figure 6.
Symbol Parameter Conditions
25 C
40 C to +85 C 40 C to +125 C Unit
Min Typ Max Min Max
Min
Max
tpd
propagation A to Y; see Figure 5
[1]
delay
VCC = 3.0 V to 3.6 V [2]
CL = 15 pF
-
3.4 7.1 1.0 8.5
1.0
10.0
ns
CL = 50 pF
-
4.9 10.6 1.0 12.0
1.0
13.5
ns
VCC = 4.5 V to 5.5 V [3]
CL = 15 pF
-
2.6 5.5 1.0 6.0
1.0
7.0
ns
CL = 50 pF
CPD
power
per buffer;
dissipation VI = GND to VCC
capacitance
-
3.6 7.0 1.0 8.0
1.0
9.0
ns
[4] -
14 -
-
-
-
-
pF
[1] tpd is the same as tPLH and tPHL.
[2] Typical values are measured at VCC = 3.3 V.
[3] Typical values are measured at VCC = 5.0 V.
[4] CPD is used to determine the dynamic power dissipation PD (W).
PD = CPD VCC2 fi + (CL VCC2 fo) where:
fi = input frequency in MHz;
74AHC1GU04_Q100
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 21 November 2012
© Nexperia B.V. 2017. All rights reserved