Electrical Characteristics (Cont’d): (TA = +25°C unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Protective Operation (Cont’d) (V9 = 15V, TA = +25°C)
External Trigger Input
V5 Enable Voltage, Vreg = 0V – 2.2 2.4
V
Disable Voltage, Vreg = 0V 2.0 2.2 –
Supply Voltage Disabling
V8 amd V1
VPin5 Zener Voltage
V19
V5 Pin5 Open
6.7 7.4 7.8
V
6.5 7.3 7.8
V
IPin5
I5
VPin5 = 3.0V
– 1.4 –
µA
VPin5 = 0V
– –11 –
Turn–On Time (Secondary Voltages)
ton
– 350 450 ms
Voltage Change
∆V2 S3 = Closed, ∆P3 = 19W
– 100 500 mV
S2 = Closed, ∆P2 = 15W
– 500 1000
Stand–By Operation
∆V2 S1 = Open
(Minimum Secondary Power: 3W)
– 20 30
V
Switching Frequency During
f
Stand–By Mode
70 75 – kHz
Primary Power Consumption
During Stand–By Mode
Pprim The Heat Sink Must Be Opti- – 10 15 VA
mized, Taking the Maximum
Data (TJ, RΘJC, TA) into
Consideration
Pin Connection Diagram
(Front View)
9 VCC
8 Source Output
7 Sink Output
6 GND
5 Shut Down
4 Sawtooth Generator
3 Feedback
2 Zero Detection
1 Reference