Models and Ratings
Output
Power(1)
225 W
Output
Voltage
5V
250 W
12 V
15 V
24 V
48 V
Output Current
Convection-cooled
18 CFM
36.0 A
45.0 A
17.0 A
21.0 A
13.5 A
17.0 A
8.5 A
10.4 A
4.3 A
5.2 A
JPS250 - Single Output
Ripple & Noise
Pk-Pk
50 mV
120 mV
120 mV
200 mV
200 mV
Efficiency
83%
86%
87%
88%
88%
Model
Number(2)
JPS250PS05C†^
JPS250PS12C†^
JPS250PS15C†^
JPS250PS24C†^
JPS250PS48C†^
Notes
1. Maximum power with 18 CFM forced air is 250 W, or 200 W with convection cooling.
2. For non-current share version delete suffix ‘C’ from model number.
Available from Farnell. See pages 204-206.
^ Available from Newark. See pages 207-208.
Mechanical Details
All dimensions are in inches (mm) Tolerance: ± 0.03 (0.8) max Weight: 1.65 lbs (750 g) approx.
All models (except JPS250PS05)
8.00 (203.2)
AB
L
N
E
TB1
3.75
(95.3)
TRANSFORMER
AB
5.50 (139.0)
6.50 (165.1)
0.30
(7.6)
A
0.75
B
(19.1)
0.36
(9.1)
JPS250PS05
AB
L
N
E
TB1
3.75
(95.3)
AB
7.40 (188.0)
8.00 (203.2)
TRANSFORMER
TB3
+
-
1.30 (32.1)
0.70 (19.1)
5.50 (139.0)
6.50 (165.1)
Application Notes
Derating Curve
100
90
L 80
O 70
A 60
D 50
40
%) 30
20
10
0
0
JPS250PS with 18 CFM Fan
JPS250PS Convection-cooled
10
20
30
40
50
Ambient Temperature (˚C)
BA
10
TB4
2
1
TB3
+
-
1
4.20
(106.7)
TB2
6
BA
A
1.51
B (38.3)
2 10
TB4
1
1
4.20
TB2
(106.7)
8
BA
PIN CONNECTIONS
TB2
Pin JPS250PS05 All other models
TB4
All models
1
+5 V
+V
Signal 0 V
2
+5 V
+V
DC OK
3
0V
+V
AC OK
4
0V
0V
Remote On/Off
5
0V
0V
+Sense
6
0V
0V
-Sense
7
+5 V
Current Share(6)
8
+5 V
N/C
9
N/C
10
N/C
Notes:
1. TB3 is for fan, with Molex 5045-02A or equivalent.
2. TB1 (AC input) and TB2 (DC output) are terminal blocks.
3. TB4 signal connector is Molex 70246-10 or equivalent.
4. Maximum mounting screw penetration is 0.16 (4.0) from chassis
outer surface.
5. Fan/Cover option available, order part number:
5 V models: JPS250 F/CVR 5^
12, 15 & 48 V models: JPS250 F/CVR^
24 V models: JPS250 F/CVR 24^
Or add suffix ‘-E’ to model number to receive unit with cover fitted.
6. For current share operation connect signal 0 V (pin 1) between
units and current share (pin 7) between units. For non ‘C’ models
pin 7 (single wire parallel) is not used.
Fixing Holes:
A = #6-32 screw mounting holes
B = M3 x 0.5 screw mounting holes
Signals
1. To turn off the output, apply 5 V to the remote On/Off.
2. AC OK is a TTL signal which goes LOW when input falls below
60 VAC at rated load.
3. DC OK is a TTL signal which goes LOW when PSU is in an
overcurrent condition, overvoltage condition, disabled or when
output falls out of regulation.
4. For AC OK and DC OK signals, source current is 1 mA, sink
current is 6 mA.
60
70
80