M74HCT651/652
DC SPECIFICATIONS
Symbol
Parameter
Test Conditions
VCC
(V)
Value
TA = 25 oC
-40 to 85 oC
Min. Typ. Max. Min. Max.
VIH High Level Input Voltage
4.5
to
5.5
2.0
2.0
VIL Low Level Input
4.5
Voltage
to
5.5
0.8
0.8
VOH High Level Output Voltage
VI = IO=-20 µA 4.4
4.5
VIH IO=-6.0 mA 4.18
or
VIL
4.5
4.31
4.4
4.13
VOL Low Level Output Voltage
VI = IO= 20 µA
4.5
VIH IO= 6.0 mA
or
VIL
0.0 0.1
0.17 0.26
0.1
0.33
II
Input Leakage Current (*)
5.5
IOZ 3 State Output Off State Current 5.5
ICC Quiescent Supply Current
5.5
∆ICC Additional worst case supply
5.5
current
(*): Applicable only to GAB, GBA, CAB, CBA, SAB, SBA input
VI = VCC or GND
VI = VCC or GND
VI = VCC or GND
Per Input pin
VI = 0.5V or
VI = 2.4V
Other Inputs at
VCC or GND
±0.1
±1
±0.5
±5.0
1
10
2.0
2.9
Unit
V
V
V
V
µA
µA
µA
mA