HA-5127, HA-5127A
Electrical Specifications VSUPPLY = ±15V, CL < 50pF, RS < 100Ω (Continued)
PARAMETER
TEMP.
HA-5127A
TEST CONDITIONS
(oC)
MIN
TYP MAX
MIN
Slew Rate
Settling Time (Note 9)
VOUT = 10V
25
7
10
-
7
25
-
1.5
-
-
Overshoot
25
-
20
40
-
POWER SUPPLY CHARACTERISTICS
Supply Current
25
-
3.5
-
-
Full
-
-
4.0
-
Power Supply Rejection Ratio
VS = ±4.5V to ±18V
Full
-
2
4
-
NOTES:
4. This parameter value is based upon design calculations.
5. Refer to Typical Performance Curves.
6. The limits for this parameter are guaranteed based on lab characterization, and reflect lot-to-lot variation.
7. Full power bandwidth guaranteed based on slew rate measurement using: FPBW = S-----l-e---w------R-----a---t--e- .
8. Refer to Test Circuits section of the data sheet.
2πVPEAK
9. Settling time is specified to 0.1% of final value for a 10V output step and AV = -1.
Test Circuits and Waveforms
HA-5127
TYP
10
1.5
20
MAX
-
-
40
3.5
-
-
4.0
16
51
UNITS
V/µs
µs
%
mA
mA
µV/V
IN
+
-
1.8kΩ
200Ω
OUT
50pF
IN
+
-
2kΩ
OUT
50pF
FIGURE 1. LARGE AND SMALL SIGNAL RESPONSE TEST CIRCUITS
IN
IN
OUT
OUT
Vertical Scale: Input = 0.5V/Div., Output = 5V/Div.
Horizontal Scale: 1µs/Div.
Vertical Scale: 100mV/Div.
Horizontal Scale: 200ns/Div.
LARGE SIGNAL RESPONSE
SMALL SIGNAL RESPONSE
5kΩ
VIN
2kΩ
+15V
2N4416
5kΩ
+15V
+
AUT
-
-15V
TO
OSCILLOSCOPE
2kΩ
50pF VOUT
NOTES:
10. AV = -1.
11. Feedback and summing resistors
should be 0.1% matched.
12. Clipping diodes are optional.
HP5082-2810 recommended.
2kΩ
FIGURE 2. SETTLING TIME TEST CIRCUIT
3
FN2906.6
July 27, 2005