Assembly
Instructions
Externally Screened Jacketed Cables
Type `B' & `Q'
Cable and Wire Stripping
Strip the outer braid and internal P.V.C. jacket of the
cable back to dim `A'.
Size
08
10,12,14
16
20
24
A Dimension
mm
58.15
66.68
69.85
88.9
95.25
in
2.89
2.625
2.75
3.50
3.75
Strip 5.3mm (0.210 in) to 6.1 mm (0.240 in) of insulation
from each wire to expose centre conductor Tin the ends. If
ends fray, twist them back to their original lay before
tinning.
Initial Assembly
Slide onto the cable the following items in this order:(1)
Nut (2) Washer (3) Male Braid Clamp - Convolute Screen
(See B) as far as possible and slide on items:(4) Female
Braid Clamp (5) Gasket (6) 75o Right Angled Body (7)
Grommet.
Solder Connection to Contacts
Insert the individual wires into the appropriate grommet
holes. At the same time, slide the grommet back as far as
possible, until the tinned ends of the centre conductors are
far enough out of the grommet to permit soldering to the
contacts. Insert the tinned ends of wires into the
appropriate contacts in 62 series connector and solder into
place. Slide the grommet forward over the wired contacts
and press firmly into the rear of connector shell and against
rear face of insert.
Unscreened Jacketed Cables Type `A'
All procedures concerning this type of cable to be as for
internally screened jacketed cable, but all references to
screen (Braid) to be disregarded.
61