Drain
Signal
NCP1378
Timeout
Signal
Drain
Signal
Demag RESTART
Current Sense and Timeout Restart
Timeout
Signal
5 ms
5 ms
Figure 19. When the primary natural ringing becomes too low, the current
sense initiates a new cycle when FB passes the skip level.
Demagnetization Detection
The core reset detection is done by monitoring the
voltage activity on the auxiliary winding. This voltage
features a FLYBACK polarity. The typical detection level
is fixed at 50 mV as exemplified by Figure 20.
7.0
5.0
POSSIBLE
RESTARTS
3.0
1.0
0V
−1.0
50 mV
TO INTERNAL
COMPARATOR
Resd
2k
3
ESD
1
4
ESD
Rdem
5
2
Aux
4
1
Figure 20. Core Reset Detection is Done through
a Dedicated Auxiliary Winding Monitoring
An internal timer prevents any restart within 8.0 ms
further to the driver going−low transition. This prevents the
switching frequency to exceed (1.0/TON + 8.0 ms) but also
Figure 21. Internal Pad Implementation
avoid false leakage inductance tripping at turn−off. In some
cases, the leakage inductance kick is so energetic, that a
slight filtering is necessary.
http://onsemi.com