MP03 XXX 275 Series
140
120
100
80
60
40
20
30˚
60˚
90˚ 120˚
180˚
00
50
100
150
200
250
300
Mean on-state current - (A)
Fig. 7 Maximum permissible case temperature vs forward current per arm at various conduction angles, sine wave, 50/60Hz
140
120
100
d.c.
80
60
40
20
30˚
60˚
90˚ 120˚
180˚
00
50
100
150
200
250
300
350
Mean on-state current - (A)
Fig. 8 Maximum permissible case temperature vs forward current per arm at various conduction angles, square wave, 50/60Hz
7/10