2-Line Filters
for General-Purpose Applications
B84110-A
Technical data
Rated voltage VR
Rated current I R
Test voltage VP
Leakage current l leak
Climatic category
Weight
250 V~, 50/60 Hz
Referred to 40 °C ambient temperature
1414 V–, 2 s (line/line)
2700 V–, 2 s (lines/ground)
< 0,5 mA at 230 V~, 50 Hz
In accordance with EN 60068-1
25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test)
approx. 53 g
Characteristics and ordering codes
IR
CR
LR
A
0,5
0,25 µF (X2)
2 × 39 mH
1
+
2 × 10 mH
2
2 × 4700 pF (Y2) 2 × 5,6 mH
4
2 × 2,7 mH
6
2 × 1,9 mH
× = approval granted
Dimensional drawing
Ordering code
Approvals
565-3
B84110-A-A5
×
×
×
B84110-A-A10 ×
×
×
B84110-A-A20 ×
×
×
B84110-A-A40 ×
×
×
B84110-A-A60
—
—
—
Mounting holes
47,5
30
1
1’
2
2’
SSB0563-9
201 03/01