Chokes for Data and Signal Lines
Quad Chokes
B82796-C2
General technical data
Rated voltage VR
Rated current IR
Rated inductance LR
Inductance tolerance
Inductance decrease ∆L/L0
Stray inductance LS
DC resistance Rtyp
Climatic category
Weight
42 Vac (50/60 Hz)
80 Vdc
Referred to 50 Hz and 60 °C ambient temperature
Measured with HP 4275A;
Measured frequency for L ≤ 1 mH = 100 kHz, 0,1 mA
L > 1 mH = 10 kHz, 0,1 mA
(specified per winding)
– 30 %/+ 50 %
< 10 % at dc magnetic bias with IR
Measured at 100 kHz and 5 mA
Typical values, measured at 20 °C ambient temperature
40/125/56 (– 40 °C/+ 125 °C/56 days damp heat test)
in accordance with IEC 60068-1
Approx. 0,4 g
Characteristics and ordering codes
LR
mH
0,011
0,047
0,47
2,2
LS, typ
IR
nH
mA
50
200
100
150
200
100
250
100
Rtyp
Ω
0,12
0,15
0,35
0,40
VT
Vdc, 2 s
750
750
750
750
Ordering code
B82796-C2113-N201
B82796-C2473-N201
B82796-C2474-N215
B82796-C2225-N265
297 04/00