B43699
High performance, compact 105 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
Leakage current Ileak
(5 min, 20 °C)
450 V DC
550 V DC at 90 °C
10 ... 47 µF
10/+30% Q
Self-inductance ESL1) Diameter d (mm)
12
13.3 14
16
18
Length l (mm)
Approx. ESL (nH)
Useful life
105 °C; VR; IAC,R
105 °C; 500 V DC; IAC,R
90 °C; VR; IAC,R
85 °C; 500 V DC; IAC,R
40 °C; VR; 2.0 IAC,R
40 °C; 500 V DC;
1.95 IAC,R
30
39
> 12500 h
> 6000 h
> 40000 h
> 30000 h
> 500000 h
> 250000 h
21
24
29
34
23
28
33
38
Requirements:
∆C/C ≤ ±30% of initial value
ESR ≤ 3 times initial specified limit
Ileak
≤ initial specified limit
Voltage endurance test
105 °C; VR
Vibration resistance test
Post test requirements:
6000 h
∆C/C ≤ ±10% of initial value
ESR ≤ 1.3 times initial specified limit
Ileak
≤ initial specified limit
To IEC 60068-2-6, test Fc:
Frequency range 10 Hz ... 55 Hz, displacement amplitude 0.75 mm,
acceleration max. 10 g, duration 3 × 2 h.
Capacitor mounted by its wire leads at a distance of (6 ±1) mm from
the case and additionally clamped by the case.
IEC climatic category
Detail specification
Sectional specification
To IEC 60068-1:
40/105/56 (40 °C/+105 °C/56 days damp heat test)
Similar to CECC 30301-801
IEC 60384-4
1) If optimum circuit design is used, the values are lower by 30%.
Please read Cautions and warnings and
Important notes at the end of this document.