AC Electrical Characteristics (Continued)
Symbol
Parameter
Conditions
VCC
TA = 25°C
TA = −40 to 85°C TA = −55 to 125°C Units
Typ
Guaranteed Limits
COUT
Maximum Output
Capacitance
15
20
20
20
pF
Note 5: CPD determines the no load dynamic power consumption, PD = CPD VCC2 f + ICC VCC, and the no load dynamic current consumption,
IS = CPD VCC f + ICC.