B32520 ... B32529
General purpose (stacked/wound)
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
Lead spacing 5 mm 7.5 mm
Technology S
S
VR
VRMS
V DC V AC dV/dt in V/µs
50 32 200
63 40 250
120
100 63 300
150
250 160 400
200
400 200 600
275
450 200
630 400 800
S = Stacked, W = Wound
10 mm
S
W
50
75
150
175
320
15 mm
S
W
30
50
5
100 10
125
20
150
22.5 mm 27.5 mm 37.5 mm
W
W
W
3
1
0.8
4
3
1
8
5
4
10
8.5 6
15
12
k0 values
Lead spacing 5 mm 7.5 mm 10 mm
Technology S
S
S
W
VR
V DC
50
63
100
VRMS
V AC k0 in V2/µs
32 20000
40 30000 15000
63 60000 30000
6300
15000
250 160 200000 100000 75000
400 200 500000 220000 140000
450 200
630 400 1000000
S = Stacked, W = Wound
400000
15 mm
S
W
22.5 mm 27.5 mm 37.5 mm
W
W
W
3800
10000
50000
100000
190000
850
5000
15000
375
800
4000
10000
18000
130
600
2500
8500
15000
100
200
2000
6000
Please read Cautions and warnings and