ADT7410
1
SCL
91
9
SDA
START
100
1
0 A1 A0 R/W
A7 A6
A1 A0
ADT7410 DEVICE ADDRESS
ACK. BY
ADT7410
REGISTER ADDRESS[A7:A0] ACK. BY
ADT7410
SR
1
9
1
9
SCL
SDA
10
A1 A0 R/W
D7 D6
D1 D0
D7 D6
D1 D0
REPEAT
START
ADT7410 DEVICE ADDRESS
ACK. BY TEMPERATURE REGISTER
ADT7410
MSB DATA
ACK. BY TEMPERATURE REGISTER
MASTER
LSB DATA
NO
ACK. BY
MASTER
NOTES
1. A START CONDITION AT THE BEGINNING IS DEFINED AS A HIGH-TO-LOW TRANSITION ON SDA WHILE SCLK REMAINS HIGH.
2. A STOP CONDITION AT THE END IS DEFINED AS A LOW-TO-HIGH TRANSITION ON SDA WHILE SCLK REMAINS HIGH.
3. THE MASTER GENERATES THE NO ACKNOWLEDGE AT THE END OF THE READBACK TO SIGNAL THAT IT DOES NOT WANT ADDITIONAL DATA.
4. TEMPERATURE REGISTER MSB DATA AND TEMPERATURE REGISTER LSB DATA ARE ALWAYS SEPARATED BY A LOW ACK BIT.
5. THE R/W BIT IS SET TO A1 TO INDICATE A READBACK OPERATION.
Figure 18. Reading Back Data from the Temperature Value Register
Rev. 0 | Page 20 of 24