Table 7. Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
IOFF
power-off leakage current VI or VO = 5.5 V; VCC = 0 V
-
ICC
supply current
VI = 5.5 V or GND; IO = 0 A;
-
VCC = 1.65 V to 5.5 V
∆ICC
additional supply current VI = VCC − 0.6 V; IO = 0 A;
-
VCC = 2.3 V to 5.5 V
[1] All typical values are measured at maximum VCC and Tamb = 25 °C.
Typ [1]
-
-
Max
±20
40
-
5 000
Unit
µA
µA
µA
Table 8. Transfer characteristics
Voltages are referenced to GND (ground = 0 V; for test circuit see Figure 9
Symbol Parameter
Conditions
−40 °C to +85 °C
Min Typ[1] Max
VT+
positive-going
see Figure 10 and
threshold voltage Figure 11
VCC = 1.8 V
VCC = 2.3 V
VCC = 3.0 V
VCC = 4.5 V
VCC = 5.5 V
VT−
negative-going see Figure 10 and
threshold voltage Figure 11
0.70 1.10 1.50
1.00 1.40 1.80
1.30 1.76 2.20
1.90 2.47 3.10
2.20 2.91 3.60
VH [2]
hysteresis voltage
VCC = 1.8 V
VCC = 2.3 V
VCC = 3.0 V
VCC = 4.5 V
VCC = 5.5 V
see Figure 10, Figure 11
and Figure 12
0.25 0.61 0.90
0.40 0.80 1.15
0.60 1.04 1.50
1.00 1.55 2.00
1.20 1.86 2.30
VCC = 1.8 V
VCC = 2.3 V
VCC = 3.0 V
VCC = 4.5 V
VCC = 5.5 V
0.15 0.49 1.00
0.25 0.60 1.10
0.40 0.73 1.20
0.60 0.92 1.50
0.70 1.02 1.70
[1] All typical values are measured at Tamb = 25 °C
[2] VH = VT+ − VT−
−40 °C to +125 °C Unit
Min
Max
0.70
1.70 V
1.00
2.00 V
1.30
2.40 V
1.90
3.30 V
2.20
3.80 V
0.25
1.10 V
0.40
1.35 V
0.60
1.70 V
1.00
2.20 V
1.20
2.50 V
0.15
1.20 V
0.25
1.30 V
0.40
1.40 V
0.60
1.70 V
0.70
1.90 V
74LVC3G14_7
Product data sheet
Rev. 07 — 12 June 2008
© NXP B.V. 2008. All rights reserved.