IFX 1117
Characteristics 3.3 V Fixed Output Voltage Device IFX1117ME V33
0 °C < Tj < 125 °C; VI = 5 V, IQ = 10 mA; unless otherwise specified.
Parameter
Symbol Limit Values Unit Measuring Conditions
min. typ. max.
Output voltage
VQ
Output voltage
VQ
Line regulation
ΔVQ
Load regulation
ΔVQ
Drop voltage
VDR
Drop voltage
VDR
Drop voltage
VDR
Drop voltage
VDR
Current consumption; Iq
Iq = II – IQ
Temperature stability ΔVQ
Long Term Stability –
3.23 3.300 3.36 V
5
5
– 3.300 – V
–1
6 mV
–1
10 mV
–2
– mV
– 1.00 1.10 V
– 1.05 1.15 V
– 1.10 1.20 V
– 1.30 1.40 V
–5
10 mA
0 mA ≤ IQ ≤ 800 mA
4.7 V ≤ VI ≤ 10 V
0 mA ≤ IQ ≤ 1000 mA;
4.7 V ≤ VI ≤ 15V
4.7 V ≤ VI ≤ 15V
0 mA ≤ IQ ≤ 800 mA;1)
0 mA ≤ IQ ≤ 1.0 A1)
IQ = 100 mA2)
IQ = 500 mA2)
IQ = 800 mA2)
IQ = 1.0 A2)
IQ = 10 mA
–
16.5 –
mV 3)
–
0.3 –
%
3)
Current limit
RMS Output Noise
IQmax
–
1100 –
– 30
Power Supply Ripple PSRR 60 65
Rejection
2250 mA
– ppm
– dB
VQ = 0.5 V
ppm of VQ, Tj = 25 °C
10 Hz ≤ f ≤ 10 kHz3)
fr = 120 Hz, Vr = 1 VPP3)
1) Measured at constant junction temperature
2) Drop voltage measured when the output voltage has dropped 100 mV from the nominal value
obtained at VI = 5.0 V.
3) Specified by design; not subject to production test.
Data Sheet
6
Rev. 1.0, 2011-02-24