HM-6551/883
TABLE 3. HM-6551B/883 AND HM-6551/883 ELECTRICAL PERFORMANCE SPECIFICATIONS
LIMITS
PARAMETER
SYMBOL
CONDITIONS
NOTE TEMPERATURE
MIN
MAX
UNITS
Input Capacitance
CI
VCC = Open, f = 1MHz, All
1
Measurements Referenced to
Device Ground
TA = +25oC
-
10
pF
Output Capacitance
CO
VCC = Open, f = 1MHz, All
1
Measurements Referenced to
Device Ground
TA = +25oC
-
12
pF
NOTE:
1. The parameters listed in Table 3 are controlled via design or process parameters are characterized upon initial design and after major
process and/or design changes.
TABLE 4. APPLICABLE SUBGROUPS
CONFORMANCE GROUPS
METHOD
SUBGROUPS
Initial Test
100%/5004
-
Interim Test
100%/5004
1, 7, 9
PDA
100%/5004
1
Final Test
100%/5004
2, 3, 8A, 8B, 10, 11
Group A
Samples/5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11
Groups C & D
Samples/5005
1, 7, 9
6-105