AS5043 Programmable 360° Magnetic Angle Encoder
22 Recommended PCB Footprint:
Recommended Footprint Data
mm
A 9.02
B 6.16
C 0.46
D 0.65
E 5.01
inch
0.355
0.242
0.018
0.025
0.197
23 Revision History
Revision
Date
1.4
Apr. 04, 2006
1.3
Sep. 27, 2005
1.2
April 11, 2005
1.1
Feb. 18.2005
1.0
Dec. 7, 2004
Description
Update Programming Sequence Figure 11; Update Prog. Conditions 19.7
Include new OTP feature: permanent enabling of analog output (see 11.1.2).
Update added features for Date Codes A534xx and higher:
Clamping levels: 10%/90% VDD, default OPAMP gain = external, red/yellow/green Magnetic field
indicator, exit alignment mode by s/w, falling edge on analog response curve on 45° and 90° modes,
jitter-free transition 360°/0° in analog mode.
Update propagation delay and thermal resistance of IC package
Add description for Analog modes and Programming
Update pin assignment and operating modes
initial revision
24 Contact
24.1 Headquarters
austriamicrosystems AG
A 8141 Schloss Premstätten, Austria
Phone: +43 3136 500 0
Fax: +43 3136 525 01
industry.medical@austriamicrosystems.com
www.austriamicrosystems.com
25 Copyright
Devices sold by austriamicrosystems are covered by the warranty and patent indemnification provisions appearing in its Term of
Sale. austriamicrosystems makes no warranty, express, statutory, implied, or by description regarding the information set forth
herein or regarding the freedom of the described devices from patent infringement. austriamicrosystems reserves the right to
change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is
necessary to check with austriamicrosystems for current information. This product is intended for use in normal commercial
applications.
Copyright © 2006 austriamicrosystems. Trademarks registered ®. All rights reserved. The material herein may not be
reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. To the best of
its knowledge, austriamicrosystems asserts that the information contained in this publication is accurate and correct. However,
austriamicrosystems shall not be liable to recipient or any third party for any damages, including but not limited to personal
injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential
damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No
obligation or liability to recipient or any third party shall arise or flow out of austriamicrosystems rendering of technical or other
services.
Revision 1.4, 04-Apr-06
www.austriamicrosystems.com