Philips Semiconductors
Stand-alone CAN controller
Product specification
SJA1000
6.3.5 STATUS REGISTER (SR)
The content of the status register reflects the status of the SJA1000. The status register appears to the microcontroller
as a read only memory.
Table 5 Bit interpretation of the status register (SR); CAN address 2
BIT
SR.7
SR.6
SR.5
SR.4
SR.3
SR.2
SR.1
SR.0
SYMBOL
NAME
BS
Bus Status; note 1
VALUE
1
0
ES
Error Status; note 2
1
TS
RS
TCS
0
Transmit Status; note 3 1
0
Receive Status; note 3 1
0
Transmission Complete 1
Status; note 4
0
TBS
Transmit Buffer Status; 1
note 5
0
DOS
RBS
Data Overrun Status; 1
note 6
0
Receive Buffer Status; 1
note 7
0
FUNCTION
bus-off; the SJA1000 is not involved in bus
activities
bus-on; the SJA1000 is involved in bus activities
error; at least one of the error counters has
reached or exceeded the CPU warning limit
ok; both error counters are below the warning limit
transmit; the SJA1000 is transmitting a message
idle; no transmit message is in progress
receive; the SJA1000 is receiving a message
idle; no receive message is in progress
complete; the last requested transmission has
been successfully completed
incomplete; the previously requested transmission
is not yet completed
released; the CPU may write a message into the
transmit buffer
locked; the CPU cannot access the transmit
buffer; a message is waiting for transmission or is
already in process
overrun; a message was lost because there was
not enough space for that message in the RXFIFO
absent; no data overrun has occurred since the
last clear data overrun command was given
full; one or more messages are available in the
RXFIFO
empty; no message is available